Anaesthetic Gas Scavenging Plant Features & Clinical Safety
Hospital-grade Anaesthetic Gas Scavenging Plant systems engineered to safeguard medical personnel and comply with ISO 7396-2 standards.
Duplex Side-Channel Blowers
Two die-cast aluminium side-channel blowers pre-piped and wired on a common skid. 100% standby redundancy ensures uninterrupted surgical theatre protection.
Automatic Duty Failover
Integrated controls continuously rotate operating hours between blowers. Automatic failover starts the standby pump immediately if differential flow deviates.
Dynamic Vacuum Relief Valve
Factory-calibrated brass relief valve maintains suction pipeline vacuum within safe limits. Prevents excessive negative pressure in surgical breathing circuits.
Spark-Proof Impellers
Side-channel impellers rotate without internal contact or mechanical oil lubrication. Eliminates friction ignition risks during flammable anesthetic vapor transfer.
Remote Theatre Activation
Compatible with BS 6834 / ISO 9170-2 theatre terminal units. Low-voltage remote switches allow surgeons and nurses to activate scavenging on demand.
Pre-Piped Isolation Manifold
Integrated non-return check valves and isolating ball valves ensure each side-channel blower can be serviced without interrupting theatre exhaust.
Airflow & BMS Telemetry
Airflow sensors and differential pressure switches detect blockages or line loss. Dedicated volt-free dry contacts interface seamlessly with hospital BMS.
Pre-Commissioned Compact Skid
Self-contained footprint built on anti-vibration rubber dampers. Shipped pre-tested and ready for immediate drop-in connection to power and piping.
Anaesthetic Gas Scavenging Plant Sub-Assemblies & AGS Plants
Factory sub-assemblies and hardware: Explore Medicabay Anaesthetic Gas Scavenging Plant side-channel blowers, control stations, and Medical Gas Scavenging System skid components engineered for Sega Systems and modern hospital AGSS System installations.

Side-Channel Blower Pump
Precision die-cast aluminium side-channel blower delivering continuous suction flow up to 270 m³/h without friction or oil lubrication.

Duplex Pump Control Panel
Automated duplex control center managing hour-balancing, automatic standby pump activation, thermal overloads, and telemetry alarms.

Remote Theatre Activation Station
Wall-mounted surgical operating room remote control switch featuring illuminated status indication and instantaneous low-voltage start commands.

Duplex Vertical Skid Assembly
Heavy-duty epoxy-coated steel baseframe accommodating twin vertical blowers, pre-installed manifolds, and anti-vibration rubber isolation dampers.

Suction & Exhaust Piping Manifold
Pre-piped copper/steel headers equipped with non-return check valves, isolation ball valves, and inline ports for seamless line connections.

Vacuum Relief & Sensing Station
Calibrated brass vacuum relief valve paired with differential pressure flow switches to maintain line suction within safe medical thresholds.
How the AGS Plant works: Operating sequence & P&ID flow
The system is activated directly from theatre remote push buttons, initiating duplex blower suction through dedicated copper pipelines to rooftop exhaust.
Theatre Remote Activation
Surgical staff press the remote push button in the operating theatre, transmitting a low-voltage start signal to the central control panel.
Terminal Unit Scavenging
Waste gases from the anaesthetic breathing circuit are drawn into the dedicated copper pipeline network through the BS 6834 terminal outlet.
Duplex Blower Suction
The control panel starts the primary side-channel blower. The vacuum relief valve regulates negative pressure to protect pipeline integrity.
Atmospheric Exhaust
Captured anaesthetic gases are safely discharged through dedicated rooftop exhaust piping, eliminating harmful exposure for hospital staff.
Anaesthetic Gas Scavenging Plant Standards & Safety
Built in strict compliance with international medical gas pipeline standards to protect healthcare professionals from occupational exposure.
ISO 7396-2 Compliance
Dedicated international benchmark governing medical anaesthetic gas scavenging pipeline systems. Regulates system sizing, minimum terminal extraction flow, and duplex pump redundancy.
HTM 02-01 & BS 6834
UK Department of Health standard defining active theatre scavenging controls, illuminated remote switch operation, and rooftop dispersion safety away from fresh air intakes.
ISO 9170-2 Gas Outlets
Standard for gas-specific anaesthetic scavenging terminal units. Ensures mechanical non-interchangeability with medical vacuum and guarantees leak-free probe engagement.
EN 1012-2 & IEC 60601
Mechanical and electrical safety standard ensuring spark-proof side-channel blower rotation, thermal overload protection, and electromagnetic immunity for central plant room controllers.