Nurse Call Systems
Medicabay HERO Series wired nurse call systems give patients and staff a reliable communication channel. Call buttons, handsets and WC pull cords in the room connect to a room address module; the room modules share one bus line to the nurse desk panel, with door top lamps in the corridor and Blue Code for life-threatening emergencies.
Units can be set up to the project before delivery.
Room and bed number, five calls at once by urgency.
Works on its own, independent of system faults.
Blue, pink and white codes above every other call.
Room and bed head light from the handset.

From the bed to the nurse desk
Each component has one job; together they make sure no call is missed.

Hero Nurse Desk Panel
The nurse desk panel receives and shows every call: a four-digit room number with the bed number or the call type, and up to five calls at once, ordered by urgency.
Audible and visual alerts change with the call type. The panel also shows the time and room temperature; one master panel can be joined by any number of slave panels, and every system setting is made from the panel.
- Rooms
- Up to 63 room address modules
- Display
- Room number, bed number or call type
- Calls shown
- Five at once, by urgency
- Clock & temperature
- Built in
- Panels
- One master, any number of slaves
- Code
- MGA.NCS.WD.DESK

Hero Room Address Module
The room address module connects the units in the room: three bed units, one WC pull cord, one door top lamp and one code call unit, with RJ45 connections.
Microprocessor controlled, it keeps working on its own if the rest of the system has a fault. It mounts in the corridor or in the bed head trunking, is protected against reverse polarity and can be changed while the system runs. Three modules give up to nine beds in one room.
- Connects
- 3 bed units, WC, door lamp, code unit
- Beds per room
- Up to 9 with three modules
- Room connection
- RJ45
- Bus line
- Up to 63 modules
- Mounting
- Corridor or bed head trunking
- Code
- MGA.NCS.WD.RMD01

Nurse Call Button & Blue Code
The nurse call button at the bed calls the nurse with a single press. The button is lit so it can be found in the dark and glows brighter to confirm the call; the cancel button shows the nurse in the room with a green light.
The emergency button starts Blue, Pink and White Code calls. To prevent false calls it is active only while a nurse is in the room; its red light flashes once the code call has started.
- Call button
- Lit, confirmation light
- Nurse in room
- Green light
- Codes
- Blue, pink and white
- Code unit
- Active with a nurse in the room
- Codes
- MGA.NCS.WD.WB01, MGA.NCS.WD.BC01

Hero Handset
The handset plugs into the bed unit and puts the call within reach of the patient.
The red button starts a call; the other two buttons switch the room light and the bed head light through the lighting module.
- Call
- Red button
- Lighting
- Room light and bed head light
- Connection
- Plugs into the bed unit
- Code
- MGA.NCS.WD.HS01

Hero WC Pull Cord
Installed in bathrooms, the pull cord lets patients alert staff at once with a red cord that is easy to reach.
Several pull cords can be connected in series to cover every point where a patient may need help.
- Cord
- Red pull cord
- Connection
- Several units in series
- Call type
- Toilet call
- Code
- MGA.NCS.WD.WB02

Hero Door Top Lamp
Mounted above the patient door, the door top lamp leads staff to the room that called and shows the call status from a distance.
It signals in red, yellow, green and blue, in an unbreakable housing. Every room has one door top lamp.
- Colours
- Red, yellow, green and blue
- Housing
- Unbreakable
- Position
- Above every patient door

Hero Lighting Control Module
The lighting control module switches the room lighting from the handset, so staff and patients need not move around the room, especially during night care.
Microprocessor controlled, it connects to the mains with two relays for two lights.
- Control
- From the handset
- Outputs
- Two relays, mains connected
- Control
- Microprocessor
- Code
- MGA.NCS.WD.LGH01
Six call types, in order of urgency
The nurse desk panel shows the most urgent call first, with its own sound and light.
Blue Code
Life-threatening emergencies, started from the code unit; the highest priority.
Pink Code
Started from the code unit while a nurse is in the room.
White Code
Started from the code unit while a nurse is in the room.
Emergency call
Started by the nurse in the room from any call unit.
Toilet call
Started with the WC pull cord, with its own sound and light.
Normal call
Started with the red button on the bed unit or the handset.
Standards & Technical Specifications for Nurse Call Systems
Common to the HERO Series wired nurse call system.
Wired bus
Room address modules share one bus line to the nurse desk; up to 63 rooms per line.
12 V DC
A central 12 V DC supply; bus on shielded twisted pair, room units on CAT5 / CAT6 with RJ45.
Up to 50 °C
For hospitals, care homes and similar facilities, up to 50 °C and 90 % humidity.
Build your nurse call system
Set the quantities for your ward. The list uses the Medicabay product codes.
Planning a project with Nurse Call Systems?