EGY Series

The Medicabay EGY Series Emergency Medical Gas Cabinet serves as a dedicated Medical Emergency Cabinet for surgical operating theatres, intensive care units, and critical recovery rooms.

This autonomous Medical Gas Emergency Cabinet provides continuous 1 to 4 gas backup. The integrated Emergency Gas Supply Cabinet architecture guarantees instantaneous failover during central pipeline drops.

100% Pneumatic Activation

Operates on pipeline pressure difference; zero electrical supply needed for gas flow.

1 to 4 Gas Configurations

Simplex, Duplex, Triplex & Quadruplex setups for O2, Air4, Air7, N2O, and CO2.

Dual Cylinder Redundancy

Two dedicated high-pressure cylinders per gas ensure seamless continuous supply.

Integrated Vacuum / AGSS

Optional built-in suction pumps handle negative pressure needs in one enclosure.

Emergency Medical Cabinets
Emergency Medical Cabinet

Emergency Medical Cabinets Engineering & Clinical Safety

Hospital-grade emergency gas stations engineered with automated pneumatic failover to safeguard surgical operating theatres and intensive care wards.

Automatic Pneumatic Failover

Self-initiating system detects pipeline pressure drops and immediately begins backup feeding without requiring manual intervention.

Two Cylinders Per Gas

Each medical gas line is supported by two high-pressure cylinders, guaranteeing continuous reserve and eliminating supply gaps.

Zero Electrical Dependency

Operates purely on mechanical pressure differentials, ensuring 100% medical gas delivery during total hospital electrical blackouts.

Pressure Restoration Control

Features manual or automatic restoring of initial pipeline pressures, granting biomedical teams complete operational flexibility.

Surface or Recessed Mounting

Engineered for surface wall-mounted installation or recessed flush in-wall architectural integration in clean corridors.

Integrated Monitoring System

Includes calibrated analog gauges and pressure sensors providing clear, instant status visibility of both cylinder and line levels.

Operating Theatre Remote Alarm

Equipped with dry contacts for operating theatre remote alarm repeaters, alerting surgical teams immediately to supply changes.

Ready-To-Run Factory Assembly

Delivered pre-tested and fully assembled. Requires only gas network connection and cylinder placement for instant deployment.

FAILOVER OPERATION & PNEUMATIC LOGIC

How Medicabay Emergency Stations Protect Operating Theatres

Step-by-step operating sequence: Learn how Emergency Medical Cabinets monitor central distribution pipelines and automatically initiate 100% pneumatic failover during unexpected pressure disruptions.

Pipeline Status: Normal Healthy Supply (4.5 Bar)
01

Continuous Pipeline Monitoring

The station continuously senses central hospital line pressure. High-pressure reserve cylinders remain fully charged on standby behind automatic shutoff regulators.

Zero Consumption
02

Pressure-Difference Activation

Upon sensing a line drop below threshold, the self-actuating pneumatic valve opens immediately. Requires zero electrical power, guaranteeing failover during blackouts.

100% Pneumatic Trigger
03

Uninterrupted Surgical Feeding

Stabilized medical gas feeds surgical theatres at exact regulated pressures. Simultaneously, volt-free contacts signal theatre remote repeaters to alert staff.

Surgical Continuity
04

Auto-Switchover & Pressure Reset

If the primary cylinder exhausts, the manifold seamlessly transitions to cylinder 2. Once central plant recovers, pressure can be restored automatically or manually.

Dual Bank Redundancy

Life-Safety Operational Principle

Medicabay EGY Series stations comply strictly with ISO 7396-1 and HTM 02-01 emergency terminal unit requirements. Non-return check valves allow empty cylinders to be hot-swapped safely under full pipeline pressure.

Standards & Certified Compliance

Manufactured and tested in accordance with international medical gas pipeline safety requirements.

Supply Protocol

HTM 02-01 & ISO 7396-1

Complies with international ISO 7396-1 pipeline requirements and UK NHS HTM 02-01 emergency terminal source protocols, ensuring uninterrupted backup gas delivery to operating theatres and ICUs.

Pressure Regulation

ISO 10524-2

Features solid brass changeover regulators certified to ISO 10524-2, controlling 200 bar cylinder inlet pressure down to stabilized 4 bar pipeline supply.

Oxygen Compatibility

ISO 15001 (O₂ Cleaned)

All internal medical brass manifolds and copper channels are degreased and certified to ISO 15001 for high-pressure medical oxygen compatibility.

EGY Cabinet Configurator ISO 7396-1 • HTM 02-01

Configure Your Emergency Cabinet by Gas Selection

Select the medical gases and suction services required for your operating theatre or ICU. The builder calculates the required cylinder capacity, manifold regulators, and generates your project specification.

1 Select Required Medical Gases (Click to toggle)
Oxygen (O₂) 2 Cylinders
4.0 - 5.0 bar • Dual Bank (1+1)
Nitrous Oxide (N₂O) 2 Cylinders
4.0 - 5.0 bar • Dual Bank (1+1)
Medical Air 4 bar 2 Cylinders
4.0 - 5.0 bar • Breathing Air
Surgical Air 7 bar 2 Cylinders
7.0 - 8.0 bar • Tool Drive
Carbon Dioxide (CO₂) 2 Cylinders
4.0 - 5.0 bar • Insufflation
Emergency Vacuum Integrated Plant
Rotary Vane Pump + Tank + Filter
2 Installation & Cylinder Standard

MGS.EGY-02G

Dual Gas Emergency Cabinet (4 Cylinders)
Selected Gases
O₂ + N₂O
Cylinder Capacity
4 Cylinders
Brass Manifolds
2 Units (CW614N)
Pipeline Pressure
4.0 - 5.0 bar
Est. Width
1100 mm
Mounting Style
Surface Mounted

Equipped with independent brass changeover blocks for each selected line, internal pressure regulators, lockable doors with observation windows, and integrated alarm telemetry.

Emergency Medical Cabinets FAQs

Essential clinical, installation, and engineering answers regarding Medicabay EGY Series emergency gas and vacuum backup cabinets.

What is the primary function of an Emergency Medical Gas Cabinet?

An Emergency Medical Gas Cabinet provides an autonomous secondary failover supply directly inside or adjacent to surgical operating suites and ICUs. If the central hospital pipeline pressure drops, the cabinet instantly maintains uninterrupted clinical gas delivery.

Where should a hospital install a Medical Emergency Cabinet?

A Medical Emergency Cabinet is strategically installed at local surgical theatre entries, trauma corridors, and recovery wings to provide instant backup gas delivery without relying on long, vulnerable distribution mains.

How does the Medical Gas Emergency Cabinet operate without electricity?

The Medical Gas Emergency Cabinet utilizes a solid brass CW614N changeover manifold that operates purely on mechanical differential pressure. It requires zero electrical power, guaranteeing 100% fail-safe activation even during complete hospital power outages.

What cylinder capacity does an Emergency Gas Supply Cabinet support?

An Emergency Gas Supply Cabinet accommodates 1 to 4 medical gases (O₂, N₂O, Medical Air 4 bar, Surgical Air 7 bar, CO₂) in dual banks holding 2 to 8 cylinders (10L, 40L, or 50L sizes), or a dedicated autonomous surgical vacuum plant.

What mounting styles are available for hospital installations?

Medicabay manufactures both Surface Mounted (on-wall) and Recessed Flush (in-wall) cabinets. Both styles feature 1.5 mm powder-coated steel enclosures, key locks, and safety observation windows for hygienic hospital corridor integration.

How does the cabinet alert theatre personnel and BMS?

Built-in pressure transducers feed a front-mounted digital alarm panel with LED line status indicators and audible alerts, alongside volt-free dry relay contacts for instant building management system (BMS) transmission.

Complete the surgical gas supply

Essential hospital source plants, pipeline controls, and surgical area safety equipment from one manufacturer.

Choose the Perfect Capacity for Your Needs

Easily find the capacity that best fits your requirements by reviewing the table below. We offer a range of options designed to meet diverse needs with maximum efficiency and reliability. Once you’ve identified the ideal capacity, don’t hesitate to reach out to us for more information, personalized assistance, or a detailed quote.