Laminar Flow Units
The Medicabay® Laminar Flow Unit is a critical system for operating rooms and hospital areas that need a hygienic, sterile environment. Linear, low-turbulent airflow through HEPA H13 / H14 filters protects both the surgical team and the patient. Made from 304 or 316 stainless steel to DIN 1946/4.
Manufactured to the dimensions of each project.
Linear, low-turbulent airflow with full-surface filter options.
HEPA H13 (99.95%) or H14 (99.995%) at MPPS.
Leakproofness and HVAC validation tests.
Low-energy LED lighting.

Laminar flow over the operating field
A stainless steel unit with HEPA filters, LED lighting and pressure monitoring, built to each room.

Laminar Flow Unit
The Medicabay® Laminar Flow Unit gives linear, low-turbulent airflow over the operating field, protecting both the surgical team and the patient to the highest standards of infection control.
Made from 304 or 316 stainless steel to DIN 1946/4, every unit is guaranteed to pass leakproofness and HVAC validation tests.
- Material
- 304 or 316 stainless steel
- Standard
- DIN 1946/4
- Airflow
- Linear, low-turbulent
- Tests
- Leakproofness, HVAC validation

HEPA Filters & Housings
HEPA H13 filters reach 99.95% and H14 filters 99.995% efficiency at the most penetrating particle size (MPPS); full-surface filter options give the widest protection.
Filter casings in MDF or galvanized steel, housings for gel filler or EPDM gaskets for airtight sealing, and slotted test points for filter tightness testing.
- Filters
- HEPA H13 (99.95%) or H14 (99.995%)
- Casing
- MDF or galvanized steel
- Gaskets
- Gel filler or EPDM
- Testing
- Slotted points for tightness tests

Airflow Surface, Lighting & Monitoring
The even airflow surface distributes the filtered air over the whole field, keeping the area sterile with minimal disruption.
Low-energy LED lighting gives bright light for less energy, and differential pressure connection probes monitor airflow integrity and performance continuously.
- Lighting
- Low-energy LED
- Monitoring
- Differential pressure probes
- Distribution
- Even airflow over the field

Customized to the Project
Each unit is manufactured to the dimensions and design of the hospital or clinic, from the room drawings.
Low-level versions are produced for rooms with limited ceiling height.
- Size
- To the project dimensions
- Low ceilings
- Low-level versions
- Input
- Room drawings
Sterile air over the patient
Reliability and precision for infection control.
304 or 316 stainless steel
Durability, corrosion resistance and ease of maintenance.
DIN 1946/4
Designed and manufactured to recognized healthcare airflow standards.
Leakproofness tested
Comprehensive leakproofness tests.
HVAC validation
All units pass HVAC validation.
HEPA H13 / H14
99.95% or 99.995% efficiency at MPPS.
Filter tightness testing
Slotted test points for full filtration integrity.
LED lighting
Bright, low-energy illumination.
Pressure monitoring
Differential pressure connection probes.
Standards & Technical Specifications for Laminar Flow Units
Common to the SLF Series laminar flow units.
DIN 1946/4
Designed and manufactured to DIN 1946/4, with leakproofness and HVAC validation tests.
HEPA H13 · H14
99.95% (H13) or 99.995% (H14) at MPPS, gel or EPDM gaskets.
304 · 316 stainless
Stainless steel body for durability, corrosion resistance and easy maintenance.
Request your laminar flow units
Set the number of units and choose the material, filter and options. Copy the list or send it to our team.
Planning a project with Laminar Flow Units?
Tell us about your facility and our team will prepare a tailored offer and technical documentation.
