Hospital Furniture • SLF Series

Laminar Flow Units

The Medicabay® Laminar Flow Unit is a critical system for operating rooms and hospital areas that need a hygienic, sterile environment. Linear, low-turbulent airflow through HEPA H13 / H14 filters protects both the surgical team and the patient. Made from 304 or 316 stainless steel to DIN 1946/4.

Key figures
H13 · H14HEPA filters
99.995%H14 efficiency
DIN 1946/4Standard
304 · 316Stainless steel

Manufactured to the dimensions of each project.

Airflow

Linear, low-turbulent airflow with full-surface filter options.

Filters

HEPA H13 (99.95%) or H14 (99.995%) at MPPS.

Validation

Leakproofness and HVAC validation tests.

Lighting

Low-energy LED lighting.

Stainless steel laminar flow unit with HEPA filters and LED lighting
SLF Series Products

Laminar flow over the operating field

A stainless steel unit with HEPA filters, LED lighting and pressure monitoring, built to each room.

Laminar Flow Unit
01 / 04 · 304 or 316 stainless steel, DIN 1946/4

Laminar Flow Unit

The Medicabay® Laminar Flow Unit gives linear, low-turbulent airflow over the operating field, protecting both the surgical team and the patient to the highest standards of infection control.

Made from 304 or 316 stainless steel to DIN 1946/4, every unit is guaranteed to pass leakproofness and HVAC validation tests.

Material
304 or 316 stainless steel
Standard
DIN 1946/4
Airflow
Linear, low-turbulent
Tests
Leakproofness, HVAC validation
HEPA Filters & Housings
02 / 04 · H13 or H14 at MPPS

HEPA Filters & Housings

HEPA H13 filters reach 99.95% and H14 filters 99.995% efficiency at the most penetrating particle size (MPPS); full-surface filter options give the widest protection.

Filter casings in MDF or galvanized steel, housings for gel filler or EPDM gaskets for airtight sealing, and slotted test points for filter tightness testing.

Filters
HEPA H13 (99.95%) or H14 (99.995%)
Casing
MDF or galvanized steel
Gaskets
Gel filler or EPDM
Testing
Slotted points for tightness tests
Airflow Surface, Lighting & Monitoring
03 / 04 · LED light, differential pressure

Airflow Surface, Lighting & Monitoring

The even airflow surface distributes the filtered air over the whole field, keeping the area sterile with minimal disruption.

Low-energy LED lighting gives bright light for less energy, and differential pressure connection probes monitor airflow integrity and performance continuously.

Lighting
Low-energy LED
Monitoring
Differential pressure probes
Distribution
Even airflow over the field
Customized to the Project
04 / 04 · Low-level versions for low ceilings

Customized to the Project

Each unit is manufactured to the dimensions and design of the hospital or clinic, from the room drawings.

Low-level versions are produced for rooms with limited ceiling height.

Size
To the project dimensions
Low ceilings
Low-level versions
Input
Room drawings
Send the room drawings to sales@medicabay.com for a unit designed to your operating room.
Design & Construction

Sterile air over the patient

Reliability and precision for infection control.

01

304 or 316 stainless steel

Durability, corrosion resistance and ease of maintenance.

02

DIN 1946/4

Designed and manufactured to recognized healthcare airflow standards.

03

Leakproofness tested

Comprehensive leakproofness tests.

04

HVAC validation

All units pass HVAC validation.

05

HEPA H13 / H14

99.95% or 99.995% efficiency at MPPS.

06

Filter tightness testing

Slotted test points for full filtration integrity.

07

LED lighting

Bright, low-energy illumination.

08

Pressure monitoring

Differential pressure connection probes.

Technical Data

Standards & Technical Specifications for Laminar Flow Units

Common to the SLF Series laminar flow units.

Standard

DIN 1946/4

Designed and manufactured to DIN 1946/4, with leakproofness and HVAC validation tests.

Filters

HEPA H13 · H14

99.95% (H13) or 99.995% (H14) at MPPS, gel or EPDM gaskets.

Material

304 · 316 stainless

Stainless steel body for durability, corrosion resistance and easy maintenance.

Quality Management

ISO 13485 & ISO 9001

Supplied under Medicabay’s ISO 13485 medical device and ISO 9001 quality management systems.

SLF Series Request

Request your laminar flow units

Set the number of units and choose the material, filter and options. Copy the list or send it to our team.

1Laminar flow units
Laminar flow unitsOne per operating room or area
1
2Material, filters and casing
3Options
Knowledge Base & Specifications

Laminar Flow Units FAQs

Clinical, installation and engineering answers about Medicabay Laminar Flow Units.

What does a laminar flow unit do?

It provides linear, low-turbulent filtered airflow over the operating field, protecting the surgical team and the patient.

Which HEPA filters are used?

H13 (99.95%) or H14 (99.995%) at MPPS.

Which standard is followed?

DIN 1946/4, with leakproofness and HVAC validation tests.

Can it fit a low ceiling?

Yes. Low-level versions are available for height-constrained spaces.

Request a quote

Planning a project with Laminar Flow Units?

Tell us about your facility and our team will prepare a tailored offer and technical documentation.

Scroll to Top