Medical Gas Delivery Units • MGO Series

Medical Gas Outlets & Probes

Medicabay produces high-quality medical gas outlets designed to international standards for safety, reliability and efficiency. The Cresta and Aura outlets are made to DIN, BS and NF norms for pendants and bed head units, together with matching probes and AGSS outlets for anaesthesia gas scavenging. Also known as medical gas terminal units.

Key figures
ISO 9170-1Outlet standard
DIN · BS · NFNorms
9Gases incl. Heliox
Double valveSafety

Order by product code, e.g. MDU.MGO.CR.DIN.00O2.

Cresta & Aura

Cresta outlets to DIN, BS and NF; Aura outlets to BS and DIN with a chromium plated brass cover.

Gases

O₂, N₂O, Entonox, MA4, SA7, CO₂, N₂, VAC, Heliox.

Safety

Double valve mechanism and colour coding for easy identification.

AGSS

Active (Venturi) and passive (pump) scavenging outlets and probes.

Aura DIN medical gas outlets
Outlet Families

Outlets and probes for every norm

Cresta and Aura outlets for each norm, AGSS scavenging outlets and the matching probes.

Cresta BS 5682 Outlets
01 / 08 · Colour-coded outlets to BS 5682

Cresta BS 5682 Outlets

The Cresta BS outlets are manufactured to BS 5682 / ISO 9170-1 and are compatible with British Standard probes.

They are available for Oxygen, nitrous oxide, Entonox, medical air 4, surgical air 7, carbon dioxide, nitrogen, vacuum and Heliox, colour coded for easy identification, with high-flow capacity and a double valve mechanism for enhanced safety.

Standard
BS 5682 / ISO 9170-1
Probes
British Standard probes
Gases
O₂, N₂O, Entonox, MA4, SA7, CO₂, N₂, VAC, Heliox
Safety
Double valve mechanism
Identification
Colour coded for each gas
Flow
High-flow capacity
Order code
MDU.MGO.CR.BS + gas
Cresta DIN 13260-2 Outlets
02 / 08 · Colour-coded outlets to DIN 13260-2

Cresta DIN 13260-2 Outlets

The Cresta DIN outlets are designed to DIN 13260-2 / ISO 9170-1 and are compatible with DIN Standard probes.

They are available for Oxygen, nitrous oxide, Entonox, medical air 4, surgical air 7, carbon dioxide, nitrogen, vacuum and Heliox, colour coded for easy identification, with high-flow capacity and a double valve mechanism for enhanced safety.

Standard
DIN 13260-2 / ISO 9170-1
Probes
DIN Standard probes
Gases
O₂, N₂O, Entonox, MA4, SA7, CO₂, N₂, VAC, Heliox
Safety
Double valve mechanism
Identification
Colour coded for each gas
Flow
High-flow capacity
Order code
MDU.MGO.CR.DIN + gas
Cresta NF S 90-116 Outlets
03 / 08 · Outlets to the French standard

Cresta NF S 90-116 Outlets

The Cresta NF outlets are designed to NF S 90-116 / ISO 9170-1 and are compatible with French Standard probes.

They are available for Oxygen, nitrous oxide, Entonox, medical air 4, surgical air 7, carbon dioxide, nitrogen, vacuum and Heliox, colour coded for easy identification, with high-flow capacity and a double valve mechanism for enhanced safety.

Standard
NF S 90-116 / ISO 9170-1
Probes
French Standard probes
Gases
O₂, N₂O, Entonox, MA4, SA7, CO₂, N₂, VAC, Heliox
Safety
Double valve mechanism
Identification
Colour coded for each gas
Flow
High-flow capacity
Order code
MDU.MGO.CR.NFS + gas
Aura BS 5682 Outlets
Aura BS 5682 Outlets, colour-coded outlets
Colour-coded Aura BS outlets for each gas
04 / 08 · Chromium plated brass cover, with or without back fixture

Aura BS 5682 Outlets

The Aura BS outlets are manufactured to BS 5682 / ISO 9170-1 with a chromium plated brass cover, compatible with British Standard probes.

They are available for Oxygen, nitrous oxide, Entonox, medical air 4, surgical air 7, carbon dioxide, nitrogen, vacuum and Heliox, with or without a back fixture, colour coded and with a double valve mechanism for enhanced safety.

Standard
BS 5682 / ISO 9170-1
Probes
British Standard probes
Gases
O₂, N₂O, Entonox, MA4, SA7, CO₂, N₂, VAC, Heliox
Safety
Double valve mechanism
Identification
Colour coded for each gas
Flow
High-flow capacity
Cover
Chromium plated brass
Order code
MDU.MGO.AR.BS + gas
Aura DIN 13260-2 Outlets
Aura DIN 13260-2 Outlets, colour-coded outlets
Colour-coded Aura DIN outlets for each gas
05 / 08 · Outlets to DIN 13260-2, with or without back fixture

Aura DIN 13260-2 Outlets

The Aura DIN outlets are designed to DIN 13260-2 / ISO 9170-1 and are compatible with DIN Standard probes.

They are available for Oxygen, nitrous oxide, Entonox, medical air 4, surgical air 7, carbon dioxide, nitrogen, vacuum and Heliox, with or without a back fixture, colour coded and with a double valve mechanism for enhanced safety.

Standard
DIN 13260-2 / ISO 9170-1
Probes
DIN Standard probes
Gases
O₂, N₂O, Entonox, MA4, SA7, CO₂, N₂, VAC, Heliox
Safety
Double valve mechanism
Identification
Colour coded for each gas
Flow
High-flow capacity
Order code
MDU.MGO.AR.DIN + gas
AGSS Active (Venturi) Outlets & Probes
06 / 08 · Anaesthesia gas scavenging with a Venturi

AGSS Active (Venturi) Outlets & Probes

The active (Venturi) anaesthesia gas scavenging outlets and probes are designed to ISO 7396-2 / EN 9170-2, with a gas-specific base block connected to the related AGSS network.

A nickel-plated brass terminal unit with identification label sits on an aluminium fixation support, with an on-off and adjusting pneumatic switch. A 4-bar compressed air supply drives the Venturi effect.

Standard
ISO 7396-2 / EN 9170-2
Drive
4-bar compressed air (Venturi)
Control
On-off and adjusting pneumatic switch
Terminal unit
Nickel-plated brass with identification label
Fixation
Aluminium support
Order codes
Outlet MDU.MGO.CR.AGS.V001, probe MDU.MGO.PR.AGS.V001
AGSS Passive (Pump) Outlets & Probes
07 / 08 · Anaesthesia gas scavenging with central pumps

AGSS Passive (Pump) Outlets & Probes

The passive (pump) anaesthesia gas scavenging outlets and probes are designed to ISO 7396-2 / EN 9170-2, with a gas-specific base block for a secure AGSS network connection.

They rely on the central AGSS pumps for effective gas evacuation, so no additional compressed air is needed. The nickel-plated brass terminal unit sits on an aluminium fixation support.

Standard
ISO 7396-2 / EN 9170-2
Drive
Central AGSS pumps, no compressed air
Terminal unit
Nickel-plated brass with identification label
Fixation
Aluminium support
Order codes
Outlet MDU.MGO.CR.AGS.P001, probe MDU.MGO.PR.AGS.P001
Medical Gas Probes
08 / 08 · DIN, BS and NF probes in brass or stainless steel

Medical Gas Probes

Medical gas probes connect medical equipment to the outlets. They are made from high-quality brass or stainless steel for long-lasting durability and resistance to corrosion.

They are manufactured to DIN, BS and NF standards for reliable, safe and consistent performance with the outlets of the same norm.

Standards
DIN, BS and NF
Material
Brass or stainless steel
Gases
O₂, N₂O, MA4, SA7, CO₂, VAC
Order code
MDU.MGO.PR + norm + gas
Outlets are supplied for the gases and norm of each project; Aura outlets are available to BS and DIN.
Design & Construction

Safe, reliable terminal units

Designed to meet international standards for safety, reliability and efficiency.

01

Standard compliance

Manufactured to DIN 13260-2, BS 5682 or NF S 90-116, all to ISO 9170-1.

02

Matching probes

Compatible with the probes of the same standard.

03

Nine gases

Oxygen, nitrous oxide, Entonox, medical air 4, surgical air 7, carbon dioxide, nitrogen, vacuum and Heliox.

04

Colour coded

Colour coding for easy identification.

05

High flow & double valve

High-flow capacity and a double valve mechanism for enhanced safety.

06

AGSS ready

Active Venturi and passive pump scavenging outlets and probes.

Safety & International Standards

Standards & Technical Specifications for Medical Gas Outlets & Probes

Every outlet is designed to the norm of the project and ISO 9170-1.

Gas Outlets

ISO 9170-1

Cresta and Aura outlets to DIN 13260-2, BS 5682 or NF S 90-116, all to ISO 9170-1.

AGSS

ISO 7396-2 / EN 9170-2

Active (Venturi) outlets with 4-bar compressed air, or passive (pump) outlets on central AGSS pumps.

Probes

DIN, BS & NF

Probes in brass or stainless steel, compatible with the outlets of the same norm.

Quality Management

ISO 13485 & ISO 9001

Manufactured under Medicabay’s ISO 13485 medical device and ISO 9001 quality management systems.

MGO Series Request List

Build your outlet and probe list

Choose the product and norm, set the quantity for each gas and add it to the list. Repeat for other outlets and probes, then request them together.

1Product and norm
2Quantities per gas
Oxygen (O₂)Catalogue code
0
Nitrous oxide (N₂O)Catalogue code
0
Medical air 4 bar (MA4)Catalogue code
0
Surgical air 7 bar (SA7)Catalogue code
0
Carbon dioxide (CO₂)Catalogue code
0
Vacuum (VAC)Catalogue code
0
EntonoxCode on request
0
Nitrogen (N₂)Code on request
0
HelioxCode on request
0
Active (Venturi)4-bar compressed air
0
Passive (pump)Central AGSS pumps
0

Knowledge Base & Specifications

Medical Gas Outlets & Probes FAQs

Clinical, installation and engineering answers about Medicabay Medical Gas Outlets & Probes.

What is a medical gas outlet?

A gas-specific terminal unit on the pipeline, mounted in pendants and bed head units, into which the probe of medical equipment is connected.

What is the difference between Cresta and Aura outlets?

Cresta outlets are made to DIN, BS and NF norms; Aura outlets to BS and DIN with a chromium plated brass cover, with or without a back fixture.

Which standards do Medicabay outlets meet?

Cresta and Aura outlets are made to DIN 13260-2, BS 5682 or NF S 90-116, all to ISO 9170-1. AGSS outlets are to ISO 7396-2 / EN 9170-2.

Which gases are available?

Oxygen, nitrous oxide, Entonox, medical air 4, surgical air 7, carbon dioxide, nitrogen, vacuum and Heliox.

What is the difference between Venturi and pump AGSS outlets?

Venturi (active) outlets need a 4-bar compressed air supply for the Venturi effect; pump (passive) outlets rely on central AGSS pumps and need no compressed air.

Are probes available?

Yes. Probes in brass or stainless steel to DIN, BS and NF standards, plus AGSS probes.

Request a quote

Planning a project with Medical Gas Outlets & Probes?

Tell us about your facility and our team will prepare a tailored offer and technical documentation.

Scroll to Top