Medical Gas Pipeline • MCP Series

Medical Copper Pipes

Medicabay provides medical copper pipes for medical gas pipeline systems: high-purity, deoxidized copper, seamless, to EN 13348 and BS EN 1057, with a clean inner surface for oxygen, nitrous oxide, carbon dioxide, medical air and vacuum. Couplings, elbows, tees, fixings and brazing rods complete a reliable installation.

Key figures
8–108 mmPipe sizes
EN 13348Standard
≤ 0.02 g/m²Inner carbon
Coils · 5 mSupply

Pipe sizes: 8, 10, 12, 15, 22, 28, 35, 42, 54, 76 and 108 mm.

Material

Cu-DHP high-purity, deoxidized copper, seamless.

Standards

Conforms to EN 13348 and BS EN 1057.

Clean inside

Total carbon ≤ 0.02 g/m², glossy inner surface.

Fittings

Couplings, elbows, tees, crosses, caps, fixings and brazing rods.

Medical copper pipes, 8 to 108 mm
MCP Series Products

Pipes, fittings and fixings

Everything for a clean, secure and leak-proof medical gas pipeline.

Medical Copper Pipes EN 13348
01 / 07 · 8 to 108 mm, coils or 5 m lengths

Medical Copper Pipes EN 13348

Medicabay medical copper pipes are made from high-purity, deoxidized copper (Cu-DHP), seamless, to EN 13348 and BS EN 1057, for the safe delivery of medical gases in healthcare facilities.

The inner surface is clean and glossy, with a total carbon content of ≤ 0.02 g/m² and free from materials incompatible with medical gases. Small sizes come in 50 m coils, all sizes in 5 m hard lengths with the wall thickness for each diameter.

Material
Cu-DHP (CW024A), Cu ≥ 99.90 %
Standards
EN 13348, BS EN 1057
Sizes
8, 10, 12, 15, 22, 28, 35, 42, 54, 76, 108 mm
Supply
50 m coils (8–12 mm) or 5 m hard lengths
Inner surface
Glossy, total carbon ≤ 0.02 g/m²
Gases
O₂, N₂O, N₂, CO₂, medical and surgical air, anaesthetic gases, vacuum
Couplings & Reducers
02 / 07 · Same or different diameters

Couplings & Reducers

Straight couplings join two pipes of the same diameter; reducing couplings join pipes of different diameters, from 10 × 8 up to 108 × 76 mm.

Solder fittings in copper for brazed, leak-proof joints, matched to the pipe sizes of the medical gas pipeline.

Couplings
10, 12, 15, 22, 28, 35, 42, 54, 76, 108 mm
Reducers
10 × 8 to 108 × 76 mm
Joint
Capillary, brazed
Elbows 45° & 90°
03 / 07 · Smooth changes of direction

Elbows 45° & 90°

45° and 90° elbows change the direction of the pipeline smoothly, keeping the flow and the cleanliness of the line.

Available for the pipe sizes of the medical gas pipeline, for brazed joints.

Angles
45° and 90°
90° elbows
8, 10, 12, 15, 22, 28, 35, 42, 54, 76, 108 mm
45° elbows
10, 12, 15, 22, 28, 35, 42, 54, 76, 108 mm
Joint
Capillary, brazed
Equal & Unequal Tees
04 / 07 · Branch connections

Equal & Unequal Tees

Equal tees make branch connections of the same diameter; unequal (reducing) tees take a smaller or larger branch, for example 22 × 15 × 22 mm.

They build the branches from the riser to every floor and every outlet.

Equal tees
10, 12, 15, 22, 28, 35, 42, 54, 76, 108 mm
Unequal tees
From 10 × 8 × 10 to 54 × 42 × 54 mm
Joint
Capillary, brazed
Crosses, End Caps & Adapters
05 / 07 · The rest of the pipeline

Crosses, End Caps & Adapters

Cross fittings distribute the flow in several directions; end caps seal unused pipe ends securely; slip couplings make repairs on existing lines.

Adapters make the transition to threaded or flanged connections at valves, outlets and equipment.

Crosses
15, 22, 28, 35 mm
End caps
10, 12, 15, 22, 28, 35, 42, 54, 76, 108 mm
Slip couplings
15 mm
Adapters
To threaded or flanged connections
Fixing Clamps, Rails, Threaded Rods & Nuts
06 / 07 · Structured, secure mounting

Fixing Clamps, Rails, Threaded Rods & Nuts

Fixing clamps hold the pipes in place and prevent movement; rails give a structured mounting for several lines side by side.

Threaded rods and nuts hang the rails from the ceiling and keep the pipeline stable and reinforced.

Clamps
For pipes 8 to 108 mm
Rails
Slotted mounting rails
Hangers
Threaded rods and nuts
Brazing Rods
07 / 07 · For leak-proof joints

Brazing Rods

Phosphor copper (CuP6, CuP7, CuP8) and silver (2 %, 5 % and 15 % Ag) brazing rods make secure, leak-proof joints between copper pipes and fittings.

Working temperatures of about 700 to 760 °C, supplied in 1 or 5 kg boxes.

Phosphor copper
CuP6, CuP7, CuP8; 2 or 3 mm, flat 3.2 × 1.2 mm
Silver
2 %, 5 % and 15 % Ag, 2 mm
Working temperature
About 700–760 °C
Packing
1 or 5 kg boxes
Pipes, fittings and fixings are supplied together for each project.
Material & Standards

Pipes for medical gases

Safe and efficient delivery of medical gases in healthcare facilities.

01

High-purity copper

Cu-DHP, deoxidized copper with at least 99.90 % Cu.

02

EN 13348 & BS EN 1057

The European and British standards for copper tubes for medical gases.

03

Clean inner surface

Total carbon ≤ 0.02 g/m², glossy, free from incompatible materials.

04

Seamless

Seamless construction for durability and safety.

05

Coils or lengths

50 m coils for small sizes, 5 m hard lengths for every size.

06

Complete installation

Fittings, fixings and brazing rods from one supplier.

Material & Standards

Standards & Technical Specifications for Medical Copper Pipes

Common to the MCP Series pipes and fittings.

Standards

EN 13348 & BS EN 1057

Seamless copper tubes for medical gases and vacuum; EN 13348 is harmonised under the Pressure Equipment Directive.

Material

Cu-DHP CW024A

Cu ≥ 99.90 %, phosphorus 0.015–0.040 %; annealed, half-hard or hard tempers.

Cleanliness

≤ 0.02 g/m² Carbon

Glossy inner surface, free from materials incompatible with medical gases.

Quality Management

ISO 13485 & ISO 9001

Supplied under Medicabay’s ISO 13485 medical device and ISO 9001 quality management systems.

MCP Series Request List

Build your pipe list

Check the pipe size, enter the pipe metres, tick the fixings and brazing rods you need and request them together. Fittings are matched to your pipeline with the quotation.

1Pipe size check

Choose the gas, the design flow and the length of the run; the pressure drop, the gas velocity and the smallest pipe within your limit are calculated.

Pressure drop–
Pressure at the far end–
Gas velocity–
Reynolds number–

Preliminary sizing only: flow in standard litres per minute (101.325 kPa, 20 °C), straight drawn copper tube, fittings not included. The final pipeline design is checked by our engineers to HTM 02-01 and ISO 7396-1.

How it is calculated
  1. Pressure drop: the Darcy–Weisbach equation (Henry Darcy, Julius Weisbach), written for isothermal gas flow: p₁² − p₂² = f · (L / D) · G² · R·T / M, where G is the mass flow per unit of pipe area.
  2. Friction factor: the Swamee–Jain equation (1976), an explicit form of the Colebrook–White equation: f = 0.25 / [log₁₀(ε / 3.7D + 5.74 / Re⁰·⁹)]²; below Re 2300 the laminar f = 64 / Re is used. Pipe roughness ε = 0.0015 mm (drawn copper).
  3. Gas density: the ideal gas law, ρ = p·M / (R·T), at the pressure and temperature you enter.
  4. Viscosity: Sutherland’s law (William Sutherland, 1893) for each gas at your temperature.
  5. Inside diameter: outside diameter minus twice the wall, per EN 13348 sizes.
2Medical copper pipes in metres

Enter the metres for each pipe size; the weight, the number of 5 m lengths and the shipping case are calculated.

Pipe (OD × wall)MetresWeight5 m lengths
8 × 1 mm––
10 × 0.6 mm––
10 × 1 mm––
12 × 0.6 mm––
12 × 1 mm––
15 × 0.7 mm––
15 × 1 mm––
22 × 0.9 mm––
22 × 1 mm––
22 × 1.5 mm––
28 × 0.9 mm––
28 × 1 mm––
28 × 1.2 mm––
28 × 1.5 mm––
35 × 1 mm––
35 × 1.2 mm––
35 × 1.5 mm––
42 × 1 mm––
42 × 1.2 mm––
42 × 1.5 mm––
54 × 1 mm––
54 × 1.2 mm––
54 × 1.5 mm––
54 × 2 mm––
76 × 1.5 mm––
76 × 2 mm––
108 × 1.5 mm––
108 × 2 mm––
108 × 2.5 mm––
Length 508 cm (5 m pipes)

3Tick the coils, fixings and brazing rods you need
8 × 1 mm
0
10 × 1 mm
0
12 × 1 mm
0
8 mm
0
10 mm
0
12 mm
0
15 mm
0
22 mm
0
28 mm
0
35 mm
0
42 mm
0
54 mm
0
76 mm
0
108 mm
0
1
1
1
Phosphor copper CuP6, 2 mm (kg)
0
Phosphor copper CuP6, 3 mm (kg)
0
Phosphor copper CuP7, 2 mm (kg)
0
Phosphor copper CuP7, 3 mm (kg)
0
Phosphor copper CuP7, flat 3.2 × 1.2 mm (kg)
0
Phosphor copper CuP8 (kg)
0
Silver brazing rod 2 % Ag, 2 mm (kg)
0
Silver brazing rod 5 % Ag, 2 mm (kg)
0
Silver brazing rod 15 % Ag, 2 mm (kg)
0
Knowledge Base & Specifications

Medical Copper Pipes FAQs

Clinical, installation and engineering answers about Medicabay Medical Copper Pipes.

Which standards do Medicabay copper pipes meet?

EN 13348 and BS EN 1057.

Which gases are the pipes suitable for?

Oxygen, nitrous oxide, nitrogen, carbon dioxide, medical and surgical air, anaesthetic gases and vacuum.

Which sizes are available?

8, 10, 12, 15, 22, 28, 35, 42, 54, 76 and 108 mm; 8 to 12 mm also in 50 m coils, every size in 5 m hard lengths.

How clean is the inside of the pipe?

The total carbon on the inner surface is at most 0.02 g/m², as EN 13348 requires.

Do you supply fittings and fixings?

Yes: couplings, reducers, 45° and 90° elbows, equal and unequal tees, crosses, end caps, slip couplings, adapters, fixing clamps, rails, threaded rods, nuts and brazing rods.

Request a quote

Planning a project with Medical Copper Pipes?

Tell us about your facility and our team will prepare a tailored offer and technical documentation.

Scroll to Top